Ductwork Services in Olivette, MO

Although your home’s ductwork is out of sight and typically out of mind, it’s incredibly important to the proper function of your AC and heating systems. Conditioned air is delivered to and returned from the rooms in your house through the ducts. 

Consequently, the duct system also plays a big part in your home’s energy efficiency and indoor air quality. 

At Classic Aire Care, we offer duct cleaning services throughout the Olivette area, using state-of-the-art equipment to clean and restore ductwork so homeowners can breathe easier! We safely, efficiently clear accumulated debris from duct systems, removing pollen, bacteria, dust, allergens, and more.

Let us help you breathe easier at home. Contact Classic Aire Care for duct cleaning services in Olivette, MO. Or call (314) 329-1943 today!

Signs You Need Air Duct Cleaning Services

These red flags may mean it’s time for air duct cleaning at your Olivette home:

  • Higher energy bills
  • Increasing amounts of dust accumulating on your countertops
  • Dirty, dusty room vents
  • Frequently clogged AC air filters, with filter replacement required more often than every 2 to 3 months
  • More allergy symptoms or attacks, like coughing or sneezing
  • Musty odors and stale air in your Olivette home

If you notice these red flags, contact Classic Aire Care online or call us at (314) 329-1943 to schedule a duct inspection at your Olivette, MO home!

Schedule Your Service Today!

Professional Duct Maintenance in the Olivette Area

Over time, as your home ages and settles, the integrity of your home’s duct system can be affected. Maintain your air ducts by having them professionally cleaned every three to five years. Do so more often if:

  • You have pets.
  • You live in areas with significant pollution.
  • Your home has just been through a dust-producing event, like a remodel. 
  • Anyone in your home has allergies, respiratory issues, or a compromised immune system.

Is Cleaning My Air Duct System Worthwhile?

Regular air duct cleaning offers many potential advantages for your family, including the following:

  • Improved energy efficiency
  • Longer service life for your HVAC system (since dust can harm HVAC equipment)
  • Better indoor air quality and less dust 
  • Reduced asthma or allergy symptoms
  • Improved home comfort

To learn more or schedule duct cleaning services at your Olivette, MO home, contact Classic Aire Care today!

Olivette Duct Cleaning Services

At Classic Aire Care, we’ve offered duct cleaning and comprehensive HVAC services to Olivette homeowners for nearly a century! With our expertise and professional duct cleaning equipment—including highly efficient vacuum devices and commercial duct cleaning brushes and sanitizers—we can thoroughly disinfect and clean your ductwork. 

We eliminate accumulated pollutants that may be lining your ducts, including lung irritants like:

  • Dust
  • Pollen
  • Mold spores
  • Pet hair and dander
  • Dust mites
  • Insect debris
  • Microscopic germs
  • And more!

Our thorough duct cleaning process ensures that debris is properly contained, with no mess left behind.

To schedule duct cleaning services in or around Olivette, contact us online or call (314) 329-1943 today.

Why Choose Classic Aire Care for Duct and HVAC Services in Olivette, MO?

At Classic Aire Care, our experienced team offers ductwork cleaning, plus duct repair, retrofitting, and replacement services. We can make sure that your duct system circulates cleaner air, with improved airflow, throughout your home. 

Contact Classic Aire Care at (314) 329-1943 to schedule duct cleaning services in Olivette, MO today!

Our Olivette HVAC company is dedicated to customer care and your complete satisfaction. We’ve provided local HVAC service for nearly 100 years, and we’re committed to offering the comfort solutions Olivette, MO residents need!

Recent Jobs and Reviews in Olivette, MO

Olivette, MO at a glance

Classic Aire Care has completed 20 jobs in Olivette, MO between August 2026 and October 2026.

The most recent job was on October 15, 2026.

Classic Aire Care has completed 91 jobs in Olivette, MO in the last 12 months.

Job Locations and Reviews

Performed a water test on the fountain supply system, inspecting the exposed valve box, riser, and PVC supply and conduit lines at the excavated site to verify proper operation. Confirmed fittings and piping were intact and the system was ready for continued fountain installation.
Performed a water test on the fountain supply system, inspecting the exposed valve box, riser, and PVC supply and conduit lines at the excavated site to verify proper operation. Confirmed fittings and piping were intact and the system was ready for continued fountain installation.
Mike A.
Mike A. Checked in
Performed a water test on the fountain supply system, inspecting the exposed valve box, riser, and PVC supply and conduit lines at the excavated site to verify proper operation. Confirmed fittings and piping were intact and the system was ready for continued fountain installation.
Olivette, MO 63132
Performed a seasonal tune-up on an 11-year-old furnace, inspecting the control board, wiring harness, flue connection, and venting for proper operation and safe connections. Noted heavy rust and corrosion on the lower cabinet panel and blower compartment guard, along with dust and debris buildup on the plenum and surrounding components, and recommended monitoring the corrosion for possible moisture or condensation issues.
Performed a seasonal tune-up on an 11-year-old furnace, inspecting the control board, wiring harness, flue connection, and venting for proper operation and safe connections. Noted heavy rust and corrosion on the lower cabinet panel and blower compartment guard, along with dust and debris buildup on the plenum and surrounding components, and recommended monitoring the corrosion for possible moisture or condensation issues.
Bryce B.
Bryce B. Checked in
Performed a seasonal tune-up on an 11-year-old furnace, inspecting the control board, wiring harness, flue connection, and venting for proper operation and safe connections. Noted heavy rust and corrosion on the lower cabinet panel and blower compartment guard, along with dust and debris buildup on the plenum and surrounding components, and recommended monitoring the corrosion for possible moisture or condensation issues.
Olivette, MO 63132
Installed a new 50-gallon Ruud Professional Grade gas water heater (Model RUGPRO50D-ePb) in accordance with permit #26PLU-20082. Applied required plumbing identification sticker to the unit and ensured all manufacturer safety labels were properly visible and intact. Installation completed to code specifications with all gas connections, venting, and water supply lines properly configured for safe operation.
Installed a new 50-gallon Ruud Professional Grade gas water heater (Model RUGPRO50D-ePb) in accordance with permit #26PLU-20082. Applied required plumbing identification sticker to the unit and ensured all manufacturer safety labels were properly visible and intact. Installation completed to code specifications with all gas connections, venting, and water supply lines properly configured for safe operation.
Bob S.
Bob S. Checked in
Installed a new 50-gallon Ruud Professional Grade gas water heater (Model RUGPRO50D-ePb) in accordance with permit #26PLU-20082. Applied required plumbing identification sticker to the unit and ensured all manufacturer safety labels were properly visible and intact. Installation completed to code specifications with all gas connections, venting, and water supply lines properly configured for safe operation.
Olivette, MO 63132
Completed comprehensive heating tune-up and safety inspection on two 9-year-old furnace units located in basement mechanical room. Performed full system diagnostics, cleaned burner assemblies, inspected heat exchangers for cracks, tested all safety controls and limit switches, checked gas pressure and combustion efficiency, lubricated blower motors, replaced air filters, and verified proper venting and airflow on both units to ensure optimal performance for the heating season.
Completed comprehensive heating tune-up and safety inspection on two 9-year-old furnace units located in basement mechanical room. Performed full system diagnostics, cleaned burner assemblies, inspected heat exchangers for cracks, tested all safety controls and limit switches, checked gas pressure and combustion efficiency, lubricated blower motors, replaced air filters, and verified proper venting and airflow on both units to ensure optimal performance for the heating season.
Brian S.
Brian S. Checked in
Completed comprehensive heating tune-up and safety inspection on two 9-year-old furnace units located in basement mechanical room. Performed full system diagnostics, cleaned burner assemblies, inspected heat exchangers for cracks, tested all safety controls and limit switches, checked gas pressure and combustion efficiency, lubricated blower motors, replaced air filters, and verified proper venting and airflow on both units to ensure optimal performance for the heating season.
Olivette, MO 63132
Completed comprehensive heating tune-up maintenance on two furnace units located in basement and attic. Performed full system diagnostics including amperage draw testing with clamp meter showing 32 amps, replaced air filter with new pleated media filter, inspected all mechanical components, verified proper electrical connections, and tested system operation. Both units are functioning within normal operating parameters following preventative maintenance service.
Completed comprehensive heating tune-up maintenance on two furnace units located in basement and attic. Performed full system diagnostics including amperage draw testing with clamp meter showing 32 amps, replaced air filter with new pleated media filter, inspected all mechanical components, verified proper electrical connections, and tested system operation. Both units are functioning within normal operating parameters following preventative maintenance service.
Brandon F.
Brandon F. Checked in
Completed comprehensive heating tune-up maintenance on two furnace units located in basement and attic. Performed full system diagnostics including amperage draw testing with clamp meter showing 32 amps, replaced air filter with new pleated media filter, inspected all mechanical components, verified proper electrical connections, and tested system operation. Both units are functioning within normal operating parameters following preventative maintenance service.
Olivette, MO 63132
Completed comprehensive heating tune-up on 10-year-old furnace unit located in basement. Performed full system inspection including burner assembly, heat exchanger, blower motor, and gas connections. Inspected and documented air filter condition and control board wiring connections. Tested all safety controls, verified proper gas valve operation, checked flue draft, and confirmed system cycling. All components found operating within manufacturer specifications with no immediate repairs required.
Completed comprehensive heating tune-up on 10-year-old furnace unit located in basement. Performed full system inspection including burner assembly, heat exchanger, blower motor, and gas connections. Inspected and documented air filter condition and control board wiring connections. Tested all safety controls, verified proper gas valve operation, checked flue draft, and confirmed system cycling. All components found operating within manufacturer specifications with no immediate repairs required.
Brandon F.
Brandon F. Checked in
Completed comprehensive heating tune-up on 10-year-old furnace unit located in basement. Performed full system inspection including burner assembly, heat exchanger, blower motor, and gas connections. Inspected and documented air filter condition and control board wiring connections. Tested all safety controls, verified proper gas valve operation, checked flue draft, and confirmed system cycling. All components found operating within manufacturer specifications with no immediate repairs required.
Olivette, MO 63132
Responded to service call for condensation issues on attic ductwork causing water damage and mold growth on interior ceiling. Inspected HVAC system including 8-year-old Lennox unit and attic ductwork installation. Found inadequate insulation on flexible ductwork allowing warm, humid attic air to contact cold supply ducts, resulting in excessive condensation formation. Condensation was dripping through ceiling penetrations at supply register, creating visible water stains, ceiling texture damage, and mold development. Assessed ductwork insulation levels and vapor barrier integrity throughout accessible attic areas. Documented existing damage to ceiling around supply vent showing cracking and deterioration from prolonged moisture exposure. Recommended proper duct insulation upgrade with vapor barrier to eliminate condensation, professional mold remediation for affected ceiling areas, and ceiling repair to restore structural integrity and appearance.
Responded to service call for condensation issues on attic ductwork causing water damage and mold growth on interior ceiling. Inspected HVAC system including 8-year-old Lennox unit and attic ductwork installation. Found inadequate insulation on flexible ductwork allowing warm, humid attic air to contact cold supply ducts, resulting in excessive condensation formation. Condensation was dripping through ceiling penetrations at supply register, creating visible water stains, ceiling texture damage, and mold development. Assessed ductwork insulation levels and vapor barrier integrity throughout accessible attic areas. Documented existing damage to ceiling around supply vent showing cracking and deterioration from prolonged moisture exposure. Recommended proper duct insulation upgrade with vapor barrier to eliminate condensation, professional mold remediation for affected ceiling areas, and ceiling repair to restore structural integrity and appearance.
Frank H.
Frank H. Checked in
Responded to service call for condensation issues on attic ductwork causing water damage and mold growth on interior ceiling. Inspected HVAC system including 8-year-old Lennox unit and attic ductwork installation. Found inadequate insulation on flexible ductwork allowing warm, humid attic air to contact cold supply ducts, resulting in excessive condensation formation. Condensation was dripping through ceiling penetrations at supply register, creating visible water stains, ceiling texture damage, and mold development. Assessed ductwork insulation levels and vapor barrier integrity throughout accessible attic areas. Documented existing damage to ceiling around supply vent showing cracking and deterioration from prolonged moisture exposure. Recommended proper duct insulation upgrade with vapor barrier to eliminate condensation, professional mold remediation for affected ceiling areas, and ceiling repair to restore structural integrity and appearance.
Olivette, MO 63132
Replaced defective blower motor on HVAC unit serial number 1725F03603 under full warranty coverage. Completed system maintenance and verified proper operation of all components. Removed and disposed of failed blower motor per standard procedures.
Replaced defective blower motor on HVAC unit serial number 1725F03603 under full warranty coverage. Completed system maintenance and verified proper operation of all components. Removed and disposed of failed blower motor per standard procedures.
Frank H.
Frank H. Checked in
Replaced defective blower motor on HVAC unit serial number 1725F03603 under full warranty coverage. Completed system maintenance and verified proper operation of all components. Removed and disposed of failed blower motor per standard procedures.
Olivette, MO 63132
Responded to main floor drain backup in basement. Upon arrival, found extensive sewage water damage in basement corner with significant black water contamination spread across floor area. Accessed cleanout location in backyard through exterior sliding door entrance. Performed time and materials cleanout service on main sewer line to clear obstruction causing basement drain backup. Successfully restored proper drainage flow through ground water drain system. Backup was resolved and system returned to normal operation.
Responded to main floor drain backup in basement. Upon arrival, found extensive sewage water damage in basement corner with significant black water contamination spread across floor area. Accessed cleanout location in backyard through exterior sliding door entrance. Performed time and materials cleanout service on main sewer line to clear obstruction causing basement drain backup. Successfully restored proper drainage flow through ground water drain system. Backup was resolved and system returned to normal operation.
John P.
John P. Checked in
Responded to main floor drain backup in basement. Upon arrival, found extensive sewage water damage in basement corner with significant black water contamination spread across floor area. Accessed cleanout location in backyard through exterior sliding door entrance. Performed time and materials cleanout service on main sewer line to clear obstruction causing basement drain backup. Successfully restored proper drainage flow through ground water drain system. Backup was resolved and system returned to normal operation.
Olivette, MO 63132
Responded to service call for non-operational upstairs HVAC system installed in July. Upon arrival, inspected 1970s-era fuse panel that had previously failed approximately one month ago requiring fuse replacement. Conducted comprehensive assessment of electrical panel condition, connections, and capacity to support newly installed heating and cooling equipment. Examined all circuit breakers, fuses, and wire terminations for signs of deterioration, overheating, or inadequate amperage rating. Photographed existing panel configuration showing aged wiring, multiple circuit connections, and overall panel condition. Inspected HVAC equipment electrical connections including capacitor, control wiring, and power supply terminations to verify proper installation and identify any contributing factors to system failure. Evaluated whether existing electrical infrastructure meets current code requirements and has sufficient capacity to reliably operate new HVAC system without repeated outages. Based
Responded to service call for non-operational upstairs HVAC system installed in July. Upon arrival, inspected 1970s-era fuse panel that had previously failed approximately one month ago requiring fuse replacement. Conducted comprehensive assessment of electrical panel condition, connections, and capacity to support newly installed heating and cooling equipment. Examined all circuit breakers, fuses, and wire terminations for signs of deterioration, overheating, or inadequate amperage rating. Photographed existing panel configuration showing aged wiring, multiple circuit connections, and overall panel condition. Inspected HVAC equipment electrical connections including capacitor, control wiring, and power supply terminations to verify proper installation and identify any contributing factors to system failure. Evaluated whether existing electrical infrastructure meets current code requirements and has sufficient capacity to reliably operate new HVAC system without repeated outages. Based
Aidan W.
Aidan W. Checked in
Responded to service call for non-operational upstairs HVAC system installed in July. Upon arrival, inspected 1970s-era fuse panel that had previously failed approximately one month ago requiring fuse replacement. Conducted comprehensive assessment of electrical panel condition, connections, and capacity to support newly installed heating and cooling equipment. Examined all circuit breakers, fuses, and wire terminations for signs of deterioration, overheating, or inadequate amperage rating. Photographed existing panel configuration showing aged wiring, multiple circuit connections, and overall panel condition. Inspected HVAC equipment electrical connections including capacitor, control wiring, and power supply terminations to verify proper installation and identify any contributing factors to system failure. Evaluated whether existing electrical infrastructure meets current code requirements and has sufficient capacity to reliably operate new HVAC system without repeated outages. Based
Olivette, MO 63132
Completed cooling system tune-up on residential AC unit located at side of home. Performed standard maintenance inspection, checked refrigerant levels registering 13.5 degrees superheat, and evaluated overall system operation. Unit exterior shows weathering and discoloration but all mechanical components functioning properly.
Completed cooling system tune-up on residential AC unit located at side of home. Performed standard maintenance inspection, checked refrigerant levels registering 13.5 degrees superheat, and evaluated overall system operation. Unit exterior shows weathering and discoloration but all mechanical components functioning properly.
Greg M.
Greg M. Checked in
Completed cooling system tune-up on residential AC unit located at side of home. Performed standard maintenance inspection, checked refrigerant levels registering 13.5 degrees superheat, and evaluated overall system operation. Unit exterior shows weathering and discoloration but all mechanical components functioning properly.
Olivette, MO 63132
Performed camera inspection of south roof drain line. Accessed drain system through interior storage closet area where plumbing infrastructure is located. Documented drain line conditions and interior access point with photographic evidence for further evaluation and recommendations.
Performed camera inspection of south roof drain line. Accessed drain system through interior storage closet area where plumbing infrastructure is located. Documented drain line conditions and interior access point with photographic evidence for further evaluation and recommendations.
John P.
John P. Checked in
Performed camera inspection of south roof drain line. Accessed drain system through interior storage closet area where plumbing infrastructure is located. Documented drain line conditions and interior access point with photographic evidence for further evaluation and recommendations.
Olivette, MO 63132
Completed scheduled HVAC maintenance on commercial cooling system serving restroom facility. Inspected air distribution components, ceiling-mounted ventilation equipment, and thermostat controls to ensure proper operation and temperature regulation throughout the space.
Completed scheduled HVAC maintenance on commercial cooling system serving restroom facility. Inspected air distribution components, ceiling-mounted ventilation equipment, and thermostat controls to ensure proper operation and temperature regulation throughout the space.
Yasin A.
Yasin A. Checked in
Completed scheduled HVAC maintenance on commercial cooling system serving restroom facility. Inspected air distribution components, ceiling-mounted ventilation equipment, and thermostat controls to ensure proper operation and temperature regulation throughout the space.
Olivette, MO 63132
Completed scheduled heating maintenance tune-up on HVAC system serving second floor zone. Inspected wall-mounted digital touchscreen thermostat control panel, confirmed proper operation and menu functionality. Accessed air handling unit, removed and inspected air filter which showed significant dust accumulation with visible debris pattern across lower section; replaced filter with new unit to restore proper airflow and system efficiency. Verified heating system operational status, all components functioning within normal parameters at time of service completion.
Completed scheduled heating maintenance tune-up on HVAC system serving second floor zone. Inspected wall-mounted digital touchscreen thermostat control panel, confirmed proper operation and menu functionality. Accessed air handling unit, removed and inspected air filter which showed significant dust accumulation with visible debris pattern across lower section; replaced filter with new unit to restore proper airflow and system efficiency. Verified heating system operational status, all components functioning within normal parameters at time of service completion.
Drake K.
Drake K. Checked in
Completed scheduled heating maintenance tune-up on HVAC system serving second floor zone. Inspected wall-mounted digital touchscreen thermostat control panel, confirmed proper operation and menu functionality. Accessed air handling unit, removed and inspected air filter which showed significant dust accumulation with visible debris pattern across lower section; replaced filter with new unit to restore proper airflow and system efficiency. Verified heating system operational status, all components functioning within normal parameters at time of service completion.
Olivette, MO 63132
Olivette, MO - Responded to no cooling call on 8-year-old Trane system with non-operational outdoor fan. Diagnosed failed dual run capacitor preventing condenser fan motor operation. Replaced defective Genteq capacitor with properly rated replacement, restored system to full cooling operation, and verified all electrical connections at contactor were secure.
Brian S.
Brian S. Checked in
Responded to no cooling call on 8-year-old Trane system with non-operational outdoor fan. Diagnosed failed dual run capacitor preventing condenser fan motor operation. Replaced defective Genteq capacitor with properly rated replacement, restored system to full cooling operation, and verified all electrical connections at contactor were secure.
Olivette, MO 63132
Responded to no cooling complaint on second floor 15-year-old Lennox system. Upon arrival, confirmed outdoor condenser unit running but indoor air handler not producing cool air. Connected manifold gauge set to service ports and performed refrigerant pressure analysis. System pressures indicated significant refrigerant undercharge. Conducted thorough leak inspection of both indoor evaporator coil and outdoor condenser coil. Inspected all refrigerant line connections, service valves, and accessible copper line sets for signs of refrigerant loss. Evaluated overall system condition noting age of equipment and wear patterns consistent with original installation. Documented findings with photos of outdoor unit with gauges attached and indoor air handler installation. Discussed system performance issues and repair options with customer. Due to age of equipment and extent of required repairs, customer elected to defer decision until Tuesday. Left system in safe condition with all service port
Responded to no cooling complaint on second floor 15-year-old Lennox system. Upon arrival, confirmed outdoor condenser unit running but indoor air handler not producing cool air. Connected manifold gauge set to service ports and performed refrigerant pressure analysis. System pressures indicated significant refrigerant undercharge. Conducted thorough leak inspection of both indoor evaporator coil and outdoor condenser coil. Inspected all refrigerant line connections, service valves, and accessible copper line sets for signs of refrigerant loss. Evaluated overall system condition noting age of equipment and wear patterns consistent with original installation. Documented findings with photos of outdoor unit with gauges attached and indoor air handler installation. Discussed system performance issues and repair options with customer. Due to age of equipment and extent of required repairs, customer elected to defer decision until Tuesday. Left system in safe condition with all service port
Roger H.
Roger H. Checked in
Responded to no cooling complaint on second floor 15-year-old Lennox system. Upon arrival, confirmed outdoor condenser unit running but indoor air handler not producing cool air. Connected manifold gauge set to service ports and performed refrigerant pressure analysis. System pressures indicated significant refrigerant undercharge. Conducted thorough leak inspection of both indoor evaporator coil and outdoor condenser coil. Inspected all refrigerant line connections, service valves, and accessible copper line sets for signs of refrigerant loss. Evaluated overall system condition noting age of equipment and wear patterns consistent with original installation. Documented findings with photos of outdoor unit with gauges attached and indoor air handler installation. Discussed system performance issues and repair options with customer. Due to age of equipment and extent of required repairs, customer elected to defer decision until Tuesday. Left system in safe condition with all service port
Olivette, MO 63132
Successfully installed a 50-gallon tall gas water heater (A.O. Smith ProMax model) in basement location. Installation included proper venting configuration with metallic ductwork, connection of hot and cold water supply lines using copper and appropriate piping materials, and installation of safety shutoff valves with green handles. All plumbing connections were completed to code specifications, gas line properly connected, and temperature/pressure relief valve installed. Work performed under plumbing permit 26PLU-17333 with licensed plumber supervision. Unit tested for proper operation, all connections inspected for leaks, and installation verified to meet manufacturer specifications and local building codes.
Successfully installed a 50-gallon tall gas water heater (A.O. Smith ProMax model) in basement location. Installation included proper venting configuration with metallic ductwork, connection of hot and cold water supply lines using copper and appropriate piping materials, and installation of safety shutoff valves with green handles. All plumbing connections were completed to code specifications, gas line properly connected, and temperature/pressure relief valve installed. Work performed under plumbing permit 26PLU-17333 with licensed plumber supervision. Unit tested for proper operation, all connections inspected for leaks, and installation verified to meet manufacturer specifications and local building codes.
Nathan A.
Nathan A. Checked in
Successfully installed a 50-gallon tall gas water heater (A.O. Smith ProMax model) in basement location. Installation included proper venting configuration with metallic ductwork, connection of hot and cold water supply lines using copper and appropriate piping materials, and installation of safety shutoff valves with green handles. All plumbing connections were completed to code specifications, gas line properly connected, and temperature/pressure relief valve installed. Work performed under plumbing permit 26PLU-17333 with licensed plumber supervision. Unit tested for proper operation, all connections inspected for leaks, and installation verified to meet manufacturer specifications and local building codes.
Olivette, MO 63132
Completed comprehensive cooling maintenance on a 9-year-old Lennox AC system with SL280UH110V060-D5 furnace. Performed standard tune-up procedures including inspection of blower assembly, verification of manufacturer specifications, and system operational testing. Unit confirmed operating properly with all components functioning within normal parameters.
Completed comprehensive cooling maintenance on a 9-year-old Lennox AC system with SL280UH110V060-D5 furnace. Performed standard tune-up procedures including inspection of blower assembly, verification of manufacturer specifications, and system operational testing. Unit confirmed operating properly with all components functioning within normal parameters.
Elijah E.
Elijah E. Checked in
Completed comprehensive cooling maintenance on a 9-year-old Lennox AC system with SL280UH110V060-D5 furnace. Performed standard tune-up procedures including inspection of blower assembly, verification of manufacturer specifications, and system operational testing. Unit confirmed operating properly with all components functioning within normal parameters.
Olivette, MO 63132
Completed time and materials piping installation work for fountain system. Reviewed technical documentation including vault installation specifications and lifting procedures with Series 2/2H vault pad sections. Installation performed according to manufacturer guidelines with proper equipment and safety protocols for underground vault positioning.
Completed time and materials piping installation work for fountain system. Reviewed technical documentation including vault installation specifications and lifting procedures with Series 2/2H vault pad sections. Installation performed according to manufacturer guidelines with proper equipment and safety protocols for underground vault positioning.
Mike A.
Mike A. Checked in
Completed time and materials piping installation work for fountain system. Reviewed technical documentation including vault installation specifications and lifting procedures with Series 2/2H vault pad sections. Installation performed according to manufacturer guidelines with proper equipment and safety protocols for underground vault positioning.
Olivette, MO 63132
Responded to reported sewer backup affecting first-floor toilet and washing machine drain. Upon inspection, identified clogged main drain line causing wastewater to back up through the plumbing stack into the laundry area. The toilet on the second floor was leaking from the stack connection, indicating pressure buildup in the system due to the blockage. 

Performed diagnostic assessment of the drainage system to locate the obstruction point. Cleared the main sewer line blockage using professional drain cleaning equipment, restoring proper flow and eliminating the backup condition. Verified that wastewater was draining correctly from both the toilet and washing machine discharge line. Inspected the stack connection at the second-floor toilet for any damage from the leak and confirmed proper sealing after clearing the blockage. 

Tested all affected fixtures to ensure complete resolution of the drainage issue and proper system function. Advised on preventative maintenance recommendations
Responded to reported sewer backup affecting first-floor toilet and washing machine drain. Upon inspection, identified clogged main drain line causing wastewater to back up through the plumbing stack into the laundry area. The toilet on the second floor was leaking from the stack connection, indicating pressure buildup in the system due to the blockage. 

Performed diagnostic assessment of the drainage system to locate the obstruction point. Cleared the main sewer line blockage using professional drain cleaning equipment, restoring proper flow and eliminating the backup condition. Verified that wastewater was draining correctly from both the toilet and washing machine discharge line. Inspected the stack connection at the second-floor toilet for any damage from the leak and confirmed proper sealing after clearing the blockage. 

Tested all affected fixtures to ensure complete resolution of the drainage issue and proper system function. Advised on preventative maintenance recommendations
La'Quan T.
La'Quan T. Checked in
Responded to reported sewer backup affecting first-floor toilet and washing machine drain. Upon inspection, identified clogged main drain line causing wastewater to back up through the plumbing stack into the laundry area. The toilet on the second floor was leaking from the stack connection, indicating pressure buildup in the system due to the blockage. Performed diagnostic assessment of the drainage system to locate the obstruction point. Cleared the main sewer line blockage using professional drain cleaning equipment, restoring proper flow and eliminating the backup condition. Verified that wastewater was draining correctly from both the toilet and washing machine discharge line. Inspected the stack connection at the second-floor toilet for any damage from the leak and confirmed proper sealing after clearing the blockage. Tested all affected fixtures to ensure complete resolution of the drainage issue and proper system function. Advised on preventative maintenance recommendations
Olivette, MO 63132

Get An Instant Online Quote

Answer 4 easy questions and get a free onscreen quote on a new furnace and A/C or water heater

request quote
Review Image
our reviews

See What Your Neighbors Are Saying

Top notch install quality. While my ac wasn’t that old, I opted for a higher efficiency heat pump system and replace my worn-out older furnace! The difference in my home is night and day difference, can’t wait to see what the bills do.

Sean K.

Sean K.

Great customer service! Called for an emergency with my furnace after hours (in the middle of winter), a mishap happened with their system. The manager Joe called me immediately in the morning, discounted my service and got Jack out in an hour. Diagnosed and fixed same…

Ebony K.

Ebony K.

I have my furnace and air conditioning system on a maintenance agreement with Classic Aire Care to be checked twice a year. They have been doing this since the system was installed eight years ago. They do excellent work and technicians are quality people. I would…

Gerald B.

Gerald B.

We enjoy the promptness and professionalism of every person we have met, encountered or had enter our home. They are very clean, neat and down-to-business kind of employees. Couldn't ask for more.

Cindy K.

Cindy K.

The Professionalism of this company as well our service technician Greg was more than just five-star rating. He took the time explained everything that he did and now my unit is running at tiptop shape.

Charles P.

Charles P.

What To Expect

Discover the Difference

100% Satisfaction Guaranteed

Over 100 Vans on The Road, Ready to Offer Same-Day Service

Over 3,000 5-Star Reviews

Free Estimates

Highly Trained Techs With Over 35 Years Of Experience

Commitment to Community

100% Satisfaction Guaranteed

Over 100 Vans on The Road, Ready to Offer Same-Day Service

Over 3,000 5-Star Reviews

Free Estimates

Highly Trained Techs With Over 35 Years Of Experience

Commitment to Community

Truck Image
Join the Classic Aire Care Membership Program

Save on Service & Enjoy Peace of Mind

  • Priority customer status
  • Discounts on repair services
  • Comprehensive maintenance & tune-ups
  • No overtime charges
  • Extended equipment life

Â