When you have an issue with your HVAC or plumbing, you want a company that you can trust. For the Creve Coeur area, our team is the answer. We’ve been servicing the Creve Coeur area since 1926, building a reputation for good work and good people.
Our work includes HVAC and plumbing services for commercial properties, homes, and 24 hours a day, 7 days a week emergency repairs. We’ve been making people comfortable since 1926 and would love to do the same for you.
Reliable Air Conditioning
While the cold snaps can be bone-rattling, the heat waves in Creve Coeur can be sweltering. To keep your home prepared for the hottest months of the year, our team offers the following AC services:
- AC repair: Whether your system won’t turn on or struggles to maintain a desired temperature, our team can inspect your system and resolve any repair needs.
- AC maintenance: Just like heating, your AC unit will be the most optimized if you have regular maintenance conducted. Our team can schedule maintenance, give you discounts, and offer additional perks when you sign up for the Planned Maintenance Agreement.
- AC installation: Need a new system or want to upgrade? Our team can help you select the best fit and install the system.
Although we work on central AC systems, that isn’t where our scope ends. Our team can also perform AC services on ductless air conditioning units and help improve indoor air quality.
If you want a free estimate on AC services for your Creve Coeur, MO, home, call (314) 329-1943 or contact us online.
(314) 329-1943Expert Heating
The last thing you want is to be stuck with no heating during a cold snap. Luckily, our team has a full suite of heating services to keep your home running strong. Our heating services include the following:
- Heating installations: With the many different heating options available, our team can help you install a new heating system or replace an existing one in your home.
- Heating maintenance: To get the most out of your heating system, you should have maintenance done at least once a year. If you want to get a tune-up without the hassle of scrambling to find an appointment, our Planned Maintenance Agreement could be an excellent fit for you.
- Heating repairs: If you feel that your heating system isn’t performing to your standards, our technicians can take a deep dive into the issue and fix any problem that could be taking place.
With how much variety exists for heating systems, our team is knowledgeable about many systems. Our team can perform heating services on boilers, furnaces, and heat pumps.
Classic Aire Care can handle all your Creve Coeur, MO, heating needs. Request a free estimate by contacting us online or calling (314) 329-1943
Top-Rated Plumbing
The plumbing system in your home can include many things. With how many items fall under plumbing, your home could collapse if your plumbing malfunctions. Luckily, the team here at Classic Aire Care is here for you.
We offer an extensive set of plumbing services. Whether you need plumbing installation, water heater services, plumbing repairs, drain cleaning, or anything in between, we’re here to help you.
To schedule plumbing services with Classic Aire Care in Creve Coeur, MO, contact us online or call (314) 329-1943
Why Choose Classic Aire Care?
We didn’t make it over 90 years by providing subpar work. Our NATE-certified technicians will give you high-quality work and ensure we leave your home better than we found it. But you don’t have to take our word for it. Instead, check out what our previous customers have had to say about their experience with us.
Classic Aire Care is the answer for any HVAC or plumbing service in Creve Coeur, MO. Schedule an appointment by calling (314) 329-1943 or contacting us online.
FAQs
Why is my AC running but not cooling?
It is a sign that you need repair work done. Chances are that something has malfunctioned with your condenser coil, which is something a professional can fix.
How do I choose a new furnace?
The needs of your home will dictate what option is best for your home. An HVAC technician can inspect your home, identify your needs, and help you select a furnace that will fulfill your needs.
Is it normal to smell gas from the water heater?
No, it is not. If you smell gas from your water heater, turn off the gas valve and schedule an appointment with an HVAC company.
Recent Jobs and Reviews in Creve Coeur, MO
Job Locations and Reviews
Responded to no cooling complaint on second floor unit of a three-unit system. Upon inspection, diagnosed low refrigerant charge on 10+ year old outdoor condenser utilizing R22 refrigerant. Added R22 refrigerant to system per manufacturer specifications, verified proper pressures and operating temperatures, and restored cooling functionality to affected zone.
Replaced evaporator coil for sunroom HVAC system located in exterior closet. Uninstalled existing furnace to access coil, then reconfigured gas line, electrical connections, and sheet metal ductwork during reinstallation. System restored to proper operation with temporary cooling maintained throughout service due to multiple systems in residence.
Completed routine cooling system tune-up on 8-year-old Lennox HVAC unit. Inspected and serviced blower assembly, verified electrical connections and wiring at terminal block, and replaced dirty pleated air filter. System operating properly with no issues identified.
Completed comprehensive cooling tune-up on 4-year-old outdoor AC unit. Performed standard maintenance protocol including inspection of condenser unit, blower wheel assembly, and all major components. Blower wheel showed moderate dust accumulation which was addressed during service, and UV light inspection was conducted as requested.
Responded to reported non-functional crystal chandelier and inoperative light switch on first floor, along with a separate lighting issue on the second floor. Performed electrical troubleshooting at the main breaker panel to identify circuit assignments and verified proper breaker operation for affected areas. Inspected the multi-tier chandelier fixture with candle-style lamps, tested switching circuits, and restored power to all reported lighting fixtures.
Replaced failed compressor under warranty on residential heat pump system. Recovered refrigerant, removed defective compressor (S/N 213427KC5F retained for warranty claim), and installed new unit. Evacuated system, charged to manufacturer specifications, and verified proper operation in both heating and cooling modes with digital diagnostics and airflow measurements.
Responded to service call for two Lennox HVAC units experiencing suboptimal cooling performance. Performed comprehensive system evaluation and preventative maintenance on both units. Replaced dirty air filter with new Filterbuy pleated media filter to restore proper airflow. Accessed air handler control compartment and inspected electrical components, control board, wiring connections, and blower assembly. Verified all connections were secure and system controls were functioning properly. Both units restored to optimal cooling operation.
Responded to clogged trench drain on back patio. Upon arrival, found linear drainage system obstructed with debris and sediment accumulation. Deployed cable snake equipment through drainage grates to clear blockage, successfully restoring proper water flow through the drainage channels.
Responded to no cooling call on 15-year-old residential AC unit. Upon arrival, found system not operating due to blown fuses in exterior disconnect box. Replaced both 50-amp FLNR time-delay fuses and restored power to unit. Verified thermostat calling for cooling and system responding properly with unit cycling on and achieving target temperature of 72°F. System tested and left operational.
Responded to no cool call on 8-year-old Lennox air conditioning system with smart thermostat display issue. Upon arrival, found AC unit operating but thermostat screen reportedly blank, preventing temperature adjustments. During diagnostic evaluation, thermostat display restored functionality and showed proper operation with touchscreen interface responding normally, displaying current temperature of 77°F, set point of 75°F in cooling mode, and outside temperature of 93°F. Verified thermostat communication with HVAC system, confirmed cooling cycle activation, and tested all control functions including temperature adjustment and mode selection. System operating as designed at time of service completion with full display and control capability restored.
Responded to no cooling complaint on upper floor unit. Upon arrival, located outdoor condensing unit on left side of home and indoor air handler in utility closet. Diagnosed system and found unit not operating properly, causing warm air distribution to upper level. Instructed customer to turn off AC unit while leaving fan running to maintain air circulation until repairs could be completed. System requires further repair work to restore cooling function.
Responded to no cooling complaint on Unit 10, a Lennox system located at ground level on side of home. Upon arrival, measured supply air temperature at floor register reading 83.5°F, confirming lack of cooling. Advised customer to shut AC off immediately and leave fan running to prevent further system damage. Documented system configuration including furnace, ductwork connections, and overall installation condition with photographic evidence for further diagnostic evaluation.
Responded to no-cooling complaint on residential air conditioning system less than 10 years old located in backyard. Upon arrival, found outdoor condenser unit significantly obstructed by overgrown vegetation including vines, branches, and dense foliage covering top and sides of equipment, restricting proper airflow to coil and fan assembly. Advised customer to turn unit off and operate in fan-only mode to prevent compressor damage. Cleared vegetation from around condenser to restore adequate clearance for airflow and heat rejection. Inspected unit for additional issues related to warm air discharge complaint. Documented equipment condition with photographs showing vegetation obstruction and weathered exterior panels. Recommended ongoing vegetation management to maintain minimum clearance requirements for optimal system performance and efficiency.
Responded to no cooling complaint on U10 system located in exterior closet alcove. Upon arrival, found unit had been shut off by customer. Performed complete system inspection of Lennox furnace and cooling components housed in brick-enclosed outdoor installation. Conducted diagnostic evaluation of refrigerant lines, electrical connections, and air handling components. Verified system operational status, checked refrigerant service valves, and inspected condensate drainage lines. Assessed humidifier integration and ductwork connections. System evaluated for proper functionality and readiness to restore cooling operation for immediate household needs.
Performed thorough cleaning of wall-mounted ductless mini-split system using jet pack cleaning equipment. Unit was accessed with ladder and deep cleaned to restore optimal airflow and system efficiency. Service completed successfully with unit operating properly upon completion.
Responded to no cooling complaint on outdoor condenser unit. Upon arrival, confirmed fan motor failure preventing proper heat rejection from the system. Inspected unit exterior condition, electrical disconnect, and surrounding installation area. Unit showed signs of age-related wear consistent with 19-year service life. Documented equipment condition and location for service records. Customer advised of findings and recommended repair options to restore cooling operation.
Responded to service call for thermostat replacement on ground-mounted outdoor unit. Upon inspection, accessed and evaluated the Emerson control board and verified all wire connections, terminal blocks, and relay components for proper operation. Photographed the control board assembly showing multiple wire terminations and electronic components to document system configuration prior to completing thermostat replacement work.
Responded to service call for 10-year-old mini split unit on sun porch ejecting black debris from discharge vents. Upon inspection, discovered extensive mold contamination and biological growth throughout evaporator coil assembly and heat exchanger fins. Performed thorough cleaning and decontamination of internal components, removed accumulated debris from blower wheel and drain system, treated affected surfaces with antimicrobial solution, and verified proper drainage function to prevent future moisture accumulation and microbial growth.
Responded to no cooling complaint on 10+ year old residential unit. Upon inspection, found outdoor unit's top filter heavily contaminated with accumulated dust, dirt, and debris causing severely restricted airflow. Indoor thermostat displayed 87°F, confirming inadequate cooling performance. Cleaned and serviced unit to restore proper operation.
# HVAC Service - No Cool Completed Responded to service call for 10+ year old outdoor condensing unit located on side of property that was not cooling and had been shut off. Upon arrival, performed visual inspection of unit exterior and internal components. Found condenser coil heavily contaminated with organic growth, algae buildup, and accumulated debris causing significant airflow restriction. Coil fins displayed greenish discoloration with darkened patches throughout, indicating extended period without maintenance. Top discharge filter panel was severely clogged with thick dust and dirt accumulation showing distinct linear patterns across entire surface. This heavy contamination was restricting airflow to compressor and fan assembly, preventing proper heat exchange and causing system shutdown. Documented existing conditions with photographs showing extent of coil contamination and filter blockage. Advised customer of findings and provided repair estimate for required cleaning se